Summary
Symptom
While doing a Find/Search in the Reference IMG (SPRO), Test Catalogs
(STWB_1) or Test Plans (STWB_2) using Ctrl+F, there are three possibilities
of error:
1) The program directly gives a Short Dump in SAPLSHI10 -
giving error messages of ABAP runtime errors - LSHI10F01 form
READ_TEXTS_FROM_INDX (or) CONNE_IMPORT_WRONG_COMP_LENG.
2) The search fails, returns - "Selected Text Not Found" even when
the Text is present in the Structure, or
3) It returns multiple hits, some of which do not display any nodes
in the Structure.
Other terms
SPRO, IMG, Test Catalog, Test Plan, STWB_1, STWB_2, SE43, SBACH04,
Search function, Ctrl+F, P_STRUCTURE_TEXTS, Short Dump
CONNE_IMPORT_WRONG_COMP_LENG.
Reason and Prerequisites
The Search function is based on a Search Index which contains the Texts
of all the nodes displayed in a Structure. If the Structure has been
modified - involving changes to the Node Texts, removal of a few nodes or
addition of new nodes - the changes are not automatically updated in the
Search Index.
So, when one performs a Search now, it could result in either of the
three symptoms mentioned above.
Solution
Refresh the Search Index using either the 'Refresh' or the 'Refresh in
Background' Buttons in the Pop-up. This process may take about 2-3 minutes.
Once finished, it gives another pop-up 'Text Index Refreshed'.
Now the Search Function will work correctly.